Product

Microswitch

Wall-mounted rectifier · 1000 A – 12 V

Compact, modular wall-mounted rectifiers with filtered-air cooling. Efficiency up to 94 %.

Find your modelSet voltage & current
24 V DC
400 A
9.6kW
Technical specifications

Specifications — MGT2 (reference model)

Compact, configurable wall-mounted rectifiers with improved efficiency. Filtered-air cooling, operation up to 40 °C (50 °C on request), shock and corrosion resistant. High-quality DC output: 0–100 % voltage and current regulation, accuracy and stability < 0.5 %, ripple < 2 %, efficiency up to 94 %.

The Microswitch range comes in several ratings; the figures below are those of the MGT2 model. Each unit is sized to your application by our engineering department.

Continuously adjustable DC output: 0–100 V · 0–400 A · CV/CC regulation. Figures for the MGT2 reference model.

0V
Max voltage
0A
Max current
0W
Output
up to
0%
Efficiency

Conversion quality

Efficiency88–94 %
Power factor> 0,98
Regulation range (U / I)0–100 %

Regulation accuracy

< 0,5 %
U / I accuracy
< 0,5 %
Stability (8 h)
< 0,5 %
Linearity
< 0,5 %
Distortion
< 2 %
Ripple

Mains input & protection

Mains voltage400 Vac 3-phase ±10 %
ConnectionNo neutral + PE
Frequency47 – 63 Hz
ProtectionOverload & short circuit

Environment & mechanical

Temperature0 to +40 °C (55 °C with derating)
Humidity85 % non-condensing
CoolingControlled forced air
Weight (MGT2)12 kg
Dimensions W×H×D320 × 350 × 230 mm

← Back to: DC rectifiers

Configuration

Options & accessories

Configure this product to match your process: control, metering and specific options. Three families of options, which can be combined to suit your application.

Interface

Control Panel

  • Manual voltage / current preset (U/I)
  • 7-segment LED displays
  • Real-time display
Touchscreen

Micronics Touch Control (MTC)

  • Touchscreen interface, built-in functions
  • Real-time I and U curves
  • Logs saved to USB stick
  • 5.7″ TFT LCD display, 262,000 colours

Panel PC

  • Touchscreen interface
  • Real-time I and U curves
  • Profile editor (ramps)
  • On / Off switch
Mounting
Remote, for cabinet integration
Remote, in an enclosure
On the front panel
Setpoint signal

Analogue

  • 0 – 10 V
  • 4 – 20 mA
  • Inputs and outputs isolated to 1500 Vrms

Digital

  • Ethernet
  • Profibus DP / PROFINET
  • 2-wire RS-485
  • Wi‑Fi
Depending on the level of control required
Active

Active meter

  • Preset counter
  • Electronic timer
Passive

Passive meter

  • Totaliser
  • Daily counter (A·h)
To be combined to suit your application

Polarity reverser

Reverses the direction of the current in the circuit — a real asset when starting up your bath.

Dual range

Optimal accuracy across two orders of magnitude, to cope with varying currents.

Sense leads

Regulation measured at the load terminals: compensates for the voltage drop in the power cables.

Ramp & timer

Voltage or current ramp-up, plus a cycle timer for controlled start-ups.

Innovation

TWIN

Dual-output rectifier: balanced current sharing from a single setpoint, with simplified wiring.

How it works

How does a rectifier work?

Four steps between your workshop mains supply and your installation.

01

The mains supply, in AC

Your installation is fed by the mains network, in alternating current. A treatment bath, however, needs direct current.

02

Conversion

The rectifier turns that alternating current into direct current, the only form your application can use.

03

Regulation

You set a voltage or current setpoint. The electronics hold it continuously, despite variations in the load and in the mains supply.

04

Output to your installation

The regulated direct current goes out to your equipment. Continuous measurement compares the result with the setpoint and corrects any deviation immediately.

Custom requirement

A specific configuration?

Our teams design solutions to match your power and environmental constraints.